The attention technical problems of the use of mechanical seal
2012-02-19

1.The static ring gland shall have sufficient strength and tighten the screws, when installation mechanical seals to ensure its transverse and vertical axis.

2.Seal line must be unblocked;It is forbidden to dry friction.

3.Hydrostatic test, observe whether there is a leak.

4.When using the temperature over 80 ℃ forced circulation way makes mechanical seal cooling should be adopted.

5.With handle gently pressing ring after installation, should scale easily and have certain elasticity;Manual jigger, should function properly.

6.Install the mechanical seal of main shaft diameter should be 0.04 mm (0.06 mm) or less, axial momentum is 0.3 mm or less, and processing according to the requirements of graphic axis and static ring corresponding parts.

7.Boot commissioning, pay attention to the presence of abnormal sound.

8.When installation, it is forbidden to collision, brutal beatings, friction pair surface should be absolutely clean.


 