1.
Mechanical seal to the accuracy requirement of the machine: the vacuum pump
mechanical seal, for example
(1) The installation of mechanical seal parts
of the shaft (or bush) the biggest radial run-out tolerance no more than 0.04 ~
0.06 mm.
(2) The rotor axial channeling can't move more than 0.3 mm.
(3) The seal cavity and end cover sealing positioning end face (or collar) on
the surface of the shaft run-out tolerance not more than 0.04 ~ 0.06 mm.
2. Mechanical seal confirmation:
(1)
Make sure that the installation whether seal is consistent with the
requirements of the model.
(2) Carefully before installation and assembly drawing, parts number is
complete.
(3) The transmission of mechanical seal, the spring has the branch of left and
right hand, to be prepared in accordance with the axis of rotation has been
selected.
3. Mechanical seal installation method:
Installation
method according to the mechanical seal type, the type of machine is different,
but the main point is almost the same installation, the installation steps and
matters needing attention are as follows:
(1) The determination of installation dimensions: when installation, should
according to the instructions on the use of the products or samples, to ensure
that the mechanical seal installation size.
(2) Before loading, axial (sleeve), gland should be no burr, bearing in good
condition;Seal, shaft, sealing cavity, gland should be cleaned.In order to
reduce frictional resistance, and shaft installed on the part of the mechanical
seal to thin coated with a layer of oil, for lubrication, considering the
intermiscibility of rubber o-ring, if not oil, but with soap and water.Without
a stop pin float mounted static ring structure, should not be oiled, into the
gland should be dry.
(3) Static ring first installed on the shaft with gland, be careful not to into
the shaft, then the ring components into.Spring bridge or transmission of the
set screws should be evenly tighten several times.
Before his fixed gland of compensation loop for axial compression with the
hand, loosen after compensation ring can automatically back no card lag
phenomenon, then gland nut evenly tied to lock.