Product Search
Industrial
Pump Company
Pump No.
Pump type
Product Series
Keys
Products & Soluctions
Home < Events < ..Before
Self-priming centrifugal pump mechanical seal installation
2010-03-30

Centrifugal pump mechanical seal of assembly interface of each component and its related before installation must clean with acetone or anhydrous alcohol clean.The installation process should be kept clean, especially the dynamic and static ring should be without impurities, dirt and auxiliary seal components.Dynamic and static ring surface coated with a layer of clean oil or turbine oil.

To tighten the gland should be performed after the coupling is find.Bolt tightening up should be uniform, prevent gland section deflection, with a feeler gauge or special tools to check each point, the error is not more than 0.05 mm.Check fit clearance of gland with shaft or sleeve diameter (and concentricity), uniform must ensure that all round, with a feeler check each point tolerance is not more than 0.10 mm.

Spring compression quantity according to provisions, there is no too big or too small, requirement of error of plus or minus 2.00 mm, will increase the section pressure, acceleration of wear and tear.Starts to cause low pressure than not sealing effect, after the spring loaded inside the spring seat flexible to move.When using a single spring to pay attention to the helical spring, spring XuanXiangYing and axis of rotation in the opposite direction.Ring of centrifugal pump mechanical seal is installed must stay flexible mobile, will ring after pressure to the spring should be able to bounce back automatically.


Service Hotline: 4008809944

views:917    lable:centrifugal pump mechanical seal ,mechanical seals, mechanical seal, seal mechanical,
News
Service Guide
Contact Us
Company:Sdms Seal Co.,Ltd.
Add:No.8, Dongsi Road Gaoxin Industrial Zone Zigong, Sichuan,China
Email:sdms1976@sdms.cn
Mobile:0086-18990090044
Tel: 0086-813-5100843
Fax: 0086-813-5100438
SDMSSEAL     In Business Since 1976