Mechanical seal of normal operation and maintenance of the problem
One, the mechanical seal before the start of
preparation and the matters needing attention
1. A comprehensive check that the mechanical
seal, and the accessory devices and pipeline installation is complete, meets
the technical requirements.
2. Before starting the mechanical seal to
static pressure test, check whether there is mechanical seal leakage
phenomenon.If the leakage is more, should find out the reason to try to
eliminate.If still invalid, should remove check and reinstall.General
hydrostatic test pressure in 2 ~ 3 kg/cm2.
3. Aaccording to the pump rotate to turning,
check whether the light evenly.Such as turning demanding or not move, should
check whether assembly size error, installation is reasonable.
Second, the mechanical seal installation and
service
1. Before the start of sealed cavity filled
with liquid shall be maintained.For solidification of the medium, the
application of steam heat seal chamber to melt medium.Prior to start turning,
in order to prevent sudden start caused by the soft ring fracture.
2. For the use of pump WaiFeng oil system of
mechanical seal, should start the sealing oil system.Stop after the last stop
in sealing system.
Not immediately stop after 3, hot oil pump
shut down the oil sealing cavity and end face seal cooling water, should be end
face seal oil temperature has dropped below 80 degrees, can stop the cooling
water, so as not to damage the sealing parts.
Third, mechanical seal
1. The pump starts if there is a slight
leakage phenomenon, should be observed for a period of time.Such as 4 hours of
continuous running, still don't reduce the leakage, should stop the pump to
check.
2. The operating pressure of the pump should
be smooth, the pressure fluctuation is not more than 1 kg/cm2.
3. Pump in operation, should avoid to occur,
in order to avoid damage in seal face dry friction and sealing.
4. Seal check regularly.In operation, when the
leak than standard, heavy oil is not more than 5 drops per minute, light oil is
not more than 10 / points, such as 2-3 days still no improvement, you should
stop the pump to check the sealing device.
SDMSSEAL | In Business Since 1976 |