First of all we have to get to
know mechanical seal should do the preparation work before and after the
maintenance:
Mechanical seal of the preparation work before
installation and the matters needing attention.
1.Iif the upgrade, please check the mechanical
seal model, the specification is correct, the quality is in accordance with the
standards;
2.Static ring tail anti-rotating groove end
and stop pin at the top should keep 1 mm - 2 mm axial clearance, lest the
buffer failure;
3.Dynamic and static ring end face wash clean
with alcohol, and the rest of the metal parts with gasoline and clean
compressed air to blow dry cleaning, carefully check business heart guarantee
the dynamic and static ring sealing surface without any damage.Before assembly,
two pieces of "0" rubber seal should be coated with a layer of lubrication
oil, dynamic and static ring end face no oil.
Mechanical seal installation sequence and
matters needing attention.
1.The relative position of the rotor and the
pump body is fixed, determine the installation position of mechanical seal,
according to the installation of the seal to the size and the position of the
static ring in the gland, measure the seal on the shaft or sleeve positioning
size;
2.Install the machine sealing ring, ring after
installation shall be guaranteed to its flexible on the shaft to move;
3.Wwill the assembled static ring and ring
assembled;
4.The sealing end cover is installed in the
seal, and the screw.
Mechanical seal is composed of high precision
parts, under the condition of correct and reasonable use, sealed performance is
good, but because of its using conditions is very complex, coupled with the
sealing structure is more complex, the performance of the mechanical seal are
easily damaged, so the reasonable maintenance and disassembly and assembly of
mechanical seal is very important.So what
mechanical seal remove the need to
pay attention to?Please look at:
Mechanical seal sealed, matters needing
attention.
Mechanical seal of the disassembly sequence is
opposite to the sequence of installation.In the process of demolition of the
mechanical seal must be carefully, can't use, with flat hammer, tapping
machine, can't can't damage the machine moving and static ring sealing surface,
if because of too much grease and other dirt, can remove, must be made after
the first wash clean with kerosene, etc and then remove, so as to keep the
machine to seal the parts in good condition.
Mechanical seal repair request and process.
Break off the plane after sealing, first
inspection on organic seal installation of pump body, must meet the following
requirements:
1.The maximum 0.05 mm or less shaft bending,
axial channeling momentum is 0.05 mm or less;
2.Ring seal to beat 0.01 mm or less;
3.Install the machine seal parts of the
surface roughness of the shaft or the shaft sleeve is 1.6 microns, and static
ring sealing surface contact with the surface roughness of 3.2 microns;
4.Then repair mechanical seal:
(1) Check each component of the mechanical
seal.All components shall be complete, nondestructive, dynamic and static ring
sealing surface without defects such as scratches, damaged, if found to have
damaged, shall be repaired or more replacement seal;
(2) Check whether the elasticity smaller, if
smaller then must replace the spring;
(3) Check the seal body wall, seal end cover
inner surface without damage, if discover the problem timely maintenance.
views:784 lable:mechanical seals, mechanical seal, mechanical seal maintenance