Product Search
Industrial
Pump Company
Pump No.
Pump type
Product Series
Keys
Products & Soluctions
Home < Events < ..Before
Analytic vacuum pump mechanical seal using requirements and installation method
2011-03-01

Installation method according to the mechanical seals type, the type of machine is different, but the main point is almost the same installation, the installation steps and matters needing attention are as follows:
1. Mechanical seal to the accuracy requirement of the machine:
1) The installation of mechanical seal parts of the shaft (or bush) the biggest radial run-out tolerance no more than 0.04 ~ 0.06 mm.
2) The rotor axial channeling can't move more than 0.3 mm.
3) The seal cavity and end cover sealing positioning end face (or collar) on the surface of the shaft run-out tolerance not more than 0.04 ~ 0.06 mm.
2. Seal confirmation:
1) Make sure that the installation whether seal is consistent with the requirements of the model.
2) Carefully before installation and assembly drawing, parts number is complete.
3) The transmission of mechanical seal, the spring has the branch of left and right hand, to be prepared in accordance with the axis of rotation has been selected.
3. Vacuum pump mechanical seal installation method:
1) The determination of installation dimensions: when installation, should according to the instructions on the use of the products or samples, to ensure that the mechanical seal installation size.
2) Before loading, axial (sleeve), gland should be no burr, bearing in good condition;Seal, shaft, sealing cavity, gland should be cleaned.In order to reduce frictional resistance, and shaft installed on the part of the mechanical seal to thin coated with a layer of oil, for lubrication, considering the intermiscibility of rubber o-ring, if not oil, but with soap and water.Without a stop pin float mounted static ring structure, should not be oiled, into the gland should be dry.
3) Static ring first installed on the shaft with gland, be careful not to into the shaft, then the ring components into.Spring bridge or transmission of the set screws should be evenly tighten several times.
Before his fixed gland of compensation loop for axial compression with the hand, loosen after compensation ring can automatically back no card lag phenomenon, then gland nut evenly tied to lock.


Service Hotline: 4008809944




views:1250    lable:mechanical seals , mechanical seal , pump seal ,vacuum pump mechnical seal,
News
Service Guide
Contact Us
Company:Sdms Seal Co.,Ltd.
Add:No.8, Dongsi Road Gaoxin Industrial Zone Zigong, Sichuan,China
Email:sdms1976@sdms.cn
Mobile:0086-18990090044
Tel: 0086-813-5100843
Fax: 0086-813-5100438
SDMSSEAL     In Business Since 1976